Laboratory Water Purification System, RO, Type 3

Hot sell lab ultra pure reverse osmosis water purification system with low price, produces Type III water / distilled water straight from tap water, conductivity of the outlet water is 0-10us/cm, suitable for general chemical/physical testing of laboratory instruments, solution preparation.
SKU: CCHN-WPS-Moro210
30-day Returns
Free Shipping
Delivery date: 6-25 days

Economical laboratory single/double stage RO water purifier system, meet general chemical analysis, laboratory equipment washing, cleaning, conventional water for testing center, pure water for autoclave.

Specification

Model Moro210s/ 220s/ 230s Moro210d/ 220d/ 230d
Process Single pass RO system Double pass RO system
Output of pure water ≥10L/H ≥10L/H
Flow rate (with pure water tank) ≥1-1.5L/min ≥1-1.5L/min
Conductivity at 25℃ ≤10μs/cm ≤5μs/cm
PH 5.0-7.5 5.0-7.5
Oxidizabes (as O) ≤0.4mg/L ≤0.4mg/L
Evaporation residue ≤2.0mg/L ≤2.0mg/L
Electrical requirements 220V (230V, 240V) 50Hz
Power ≥100W ≥150W
Dimension (L/W/H) 340*550*530mm 340*550*530mm
Weight ≥30KG ≥35KG
Tank capacity 210s/210d (3 Gallon pressure tank)
220s/220d (6.5 Gallon pressure tank)
230s/230d (10 Gallon pressure tank)

Note: The model end with 's' has single stage RO module, suitable for feed water inlet TDS<200PPM. Model end with 'd' have double stage RO module, suitable for feed water inlet 200ppm400PPM, suggest an additional industrial type softener.

Product Features
Integrated tabletop water purifier for Type III water.
Pure deionized/distilled water.
Built-in RO membrane anti-scaling program, RO membrane cleaning manual button.
Easy to clean, disinfect and discharge waste water.
Conductivity is displayed on the LED screen.
Variable outlet capacity from 5LPH to 100LPH.

Lab Test and Corresponding Water Type List

Test Name Type III Water Type II Water Type I Water
Lab glassware washing    
Hydroponics    
Sterilizer use water    
Gas generator use water  
Conventional test    
Reagents/ drugs preparation, dilution    
Feed water for ultrapure water    
IC    
LC/LC-MS    
HPLC    
AAS    
ICP/ICP-MS    
GC/GC-MS    
Trace analysis    
TOC analysis    
Organic analysis    
Inorganic analysis    
Environmental analytical test    
Microelectronics parts cleaning    
Precision instrument use water    
Analytical reagent/ drugs preparation, dilution    
Mass spectrometry    
PCR application/analysis    
DNA/RNA research    
Proteomics research    
Plant and animal cell culture    
Toxicity analysis    
Microbiology experiment    
Immunological experiment    
Biochemistry experiment    
Serum test    
IVF    

Main Consumable List (A water purification system is equipped with a set of consumables. If you want to buy some of the following consumables, contact us now.)

No. Name Specification Lifespan
1 PP filter 1st stage, 10”/20” (5μm) 3-6 months
2 Activated Carbon filter 2nd stage, 10”/20” 6-12 months
3 Softener filter 3rd stage, 10”/20” 6-12 months
4 Precision filter 4th stage, 10”/20” (1μm) 10-12 months
5 RO membrane 75g/300g 1-2 years
6 Ultra purification resin column   1 year
7 Micro filter 0.22μm 1 year
8 UV lamp 185/254nm 8000 hours
9 Pure water tank 30L, 80L, 120L  

Tips: How to avoid damage to reverse osmosis (RO) membrane?
There are many situations that cause reverse osmosis membrane damage. In the daily experiment process, laboratory personnel do not pay much attention to the use of equipment, so the service life of the ultrapure water system is also shortened. What should be paid attention to in daily use?
1. Raw water quality
The water used in the laboratory is mostly tap water, and the quality of the water source varies from region to region. The macromolecular substances in the raw water are not completely removed and pass into the reverse osmosis membrane when they pass through the pre-treatment device of the laboratory purification water system, which easily causes the reverse osmosis membrane to be blocked.
2. Improper operation
The residual gas in the purification water system runs under high pressure, and the formation of an air hammer will damage the RO membrane. Therefore, it must be ensured that the remaining air is exhausted under the pressure of 2 to 4 bar, and then the pressure is gradually increased.
If the device is turned on repeatedly, it will cause unstable pump pressure and even cause RO membrane breakdown.
3. Poor disinfection
If the RO membrane is used for a long period of time without regular disinfection or good disinfection, it will also cause the membrane to be contaminated with a large number of microorganisms, and long-term accumulation will cause damage to the RO membrane.
4. RO membrane pre-treatment filter is not maintained properly
Pre-treatment is mainly used to filter large particulate matter, colloids, gas, etc. in water quality, and these materials also cause great damage to RO reverse osmosis. Internally filled activated carbon generally needs to be replaced within 1-3 years, and PP cotton needs to be replaced within 6-12 months.
5. Not used for a long time
When the ultra-pure water machine is not used for a long time, the RO membrane will dry out, and the filtered impurities will be fixed on the RO membrane. When we use it again, tap water cannot pass through the RO membrane. So even if we don’t use water, we still need to turn on the machine from time to time to clear the inside.