AC 220V SCR Voltage Regulator

SCR voltage regulator changes voltage value on the load by phase-shift triggering, can continuously adjust the voltage on load. Adjustment range is 0-220VAC. There are three control output types for selection. The main output characteristic is stabilized voltage output. Small size, light weight, high accuracy, strong earthquake resistance, and affordable price.
SKU: CCHN-VRG-220
30-day Returns
Free Shipping
Delivery date: 6-25 days

Features

  • Double-row LED digital display, real-time display of the current voltage.
  • High accuracy, strong shock resistance, good reliability, strong anti-interference ability, easy operation.
  • Adopt voltage negative feedback technology to stabilize AC voltage.

Specification

Model CCHN-ZKG-2000-1 CCHN-ZKG-3000-2B CCHN-ZKG-300-3B CCHN-ZKG-2000A-2A CCHN-ZKG-2000A-3A CCHN-ZKD-6000-2A CCHN-ZKD-6000-3A
Control Output Type Control SSR-DV Module Control 1 pc of Two-Way controlled Silicon Control 2 pc of Antiparallel SCR or 1 pc of SKKT Control 1 pc of Two-Way controlled Silicon Control 2 pc of Antiparallel SCR or 1 pc of SKKT Control 1 pc of Two-Way controlled Silicon Control 2 pc of Antiparallel SCR or 1 pc of SKKT
Overall Dimension (L*W*H) 48mm*48mm*90mm 48mm*48mm*107mm 48mm*48mm*75mm 72mm*72mm*120mm
Opening Dimension (L*W) 45mm*45mm 45mm*45mm 45mm*45mm 67mm*67mm
Working Voltage AC 220V 50Hz (Other voltages can customize)
Adjustment Range 0-220VAC
Ambient Temperature -5℃~40℃
Relative Humidity ≤85% in non corrosive gas occasion
Main Output Characteristic Stabilized Voltage Output
Certification CE
Installation Mode Panel Type
Power Consumption 3W

Dimension Drawing Example

Dimension Drawing Example of 220V AC SCR Voltage RegulatorDetails

AC 220V SCR Voltage Regulator Details

Usage and Adjustment

  1. Switch the POWER to ON and the voltage regulator will work.
  2. Adjust the plus key ∧ or minus key ∨ on panel to make the voltage on load displayed by PV reach the required value or change the set voltage value displayed on SV.
  3. SCR voltage regulator uses negative voltage feedback. It is strictly forbidden to supply half-wave power to the load, so as to prevent the DC current on load from burning feedback transformer inside the instrument. In daily use, it is also necessary to prevent the unilateral conduction of the SCR.
  4. Do not drive inductive loads such as induction furnaces and step-down transformers to prevent damage to the SCR.
  5. If the SCR cannot be fully conducted or the output is severely jittered, it is caused by reverse connection of the trigger connection wires. Exchange the two trigger signal output wires to each other.