| Model |
CCHN-NTS-750-112 |
| AC Output |
| Rated Power (Continuous) |
750W |
| Over Rated Power (3 Min.) |
862W |
| Peak Power (10 Sec.) |
1125W |
| Surge Power (30 Cycles) |
1500W |
| AC Voltage |
Default setting set at 110VAC |
| 100/110/115/120Vac selectable by DIP S.W |
| Frequency |
Default setting set at 60Hz±0.1Hz |
| 50/60Hz selectable by DIP S.W |
| Waveform |
True sine wave (THD < 3%) |
| AC Regulation |
± 3.0% at rated output voltage |
| DC Input |
| DC Voltage |
12V |
| Voltage Range |
10~16.5Vdc |
| Direct Current |
75A |
| No-load Protection |
Non Saving Mode |
| Saving Mode 1.2W, Default disable, ≦1.2W ~ 1.5W by models @ auto detect AC output load ≦10W will be changed to saving mode |
| Off Mode Current |
≦1mA |
| Efficiency |
0.89 |
| Battery Type |
Lead Acid or li-ion |
| DC Input Protection |
| Fuse Internal |
40A*3 |
| Low Pressure Alarm |
11±0.3Vdc |
| Low Pressure Shutdown |
10±0.3Vdc |
| Low Pressure Restart |
12.5±0.3Vdc |
| High Pressure Alarm |
15.5±0.3Vdc |
| High Pressure Shutdown |
16.5±0.3Vdc |
| High Pressure Restart |
15±0.3Vdc |
| Battery Reverse |
By internal fuse open |
| AC Output Protection |
| Over Temperature |
Protection mode: output voltage off, restored after reboot.Output voltage is switched off and restored automatically when the temperature drops. |
| Output Short |
Protection type: Shut down o/p voltage, re-power on to recover |
| Over Load (Typ.) |
105~115% load for 180 sec., 115% ~ 150% load for 10 sec. |
| Protection type: Shut down o/p voltage, re-power on to recover |
| Function |
| Remote Control |
Dry contact: Power ON-OFF remote control by front panel dry contact connector (by RELAY), Open : Normal work ; Short : Remote off |
| Accessories: Remote controller sold separately |
| RS-232 Communication |
Refer to PDF below the table |
| Operating Humidity |
20%~90% RH non-condensing |
| Size |
270*158*67mm (L*W*H) |