A 3 hp magnetic drive pump refers to a type of industrial pump that utilizes magnetic coupling to transfer power from the motor to the pump impeller without a direct mechanical connection. Magnetic drive centrifugal pump adaptable to IEC standard motor. This type of pump is suitable forchemical industry and metal industry.
Features:
- ETFE (carbon-fiber reinforced) wetted-end material.
- Able to handle many types of chemical and temperature up to 90 ℃.
- Available in flange connections.
Specification:
| Model |
CCHN-353PW-F |
| Specific Gravity |
1.2 |
| Frequency |
50Hz, 60Hz |
| Rated Voltage |
3-phase 380V (please contact us for other voltages) |
| Pump performance at specific point (M-L/min) |
50Hz |
24-150 |
| 60Hz |
32-120 |
| Motor Output |
3 HP (2.2 kW) |
| Flange Size |
32 mm (outlet); 32 mm (inlet) |
| Casing Material |
ETFE |
| Shaft Material |
ceramic |
| Bearing Material |
carbon |
| O-ring Material |
FKM |
| Interface Mode |
thread, flange |
| Net Weight |
46kg |
Structure:

Dimension (Unit: mm)

| Model |
W |
H |
L |
a |
b |
c |
d |
e |
f |
| 352PW-F |
160 |
242 |
505.5 |
222.5 |
132 |
155 |
130 |
120 |
78 |
Tips: How to Prime a Magnetic Drive Pump?
- Ensure the magnetic drive pump is turned off and disconnected from the power source.
- Open the suction valve on the inlet side of the pump.
- Pour liquid into the inlet until the pump is filled.
- Close the suction valve.
- Turn on the pump and let it run for a few seconds to ensure that it is working properly.
It is important to never run a magnetic drive pump dry as this can cause damage to the pump. Always ensure that the pump is primed with the appropriate fluid before turning it on.