Chloride Ion Selective Electrode

ATO chloride ion-selective electrode (ISE) is a sensor used with a reference electrode and ion meter in analytical chemistry to measure the concentration of chloride ions (Cl-) in a solution, measuring range from 5x10-5~10-1mol/L. The low price specific electrode consists of a membrane selective to chloride ions, made of silver chloride, surrounded by a reference solution containing a fixed concentration of chloride ions.
SKU: CCHN-ISE-CHLORIDE
30-day Returns
Free Shipping
Delivery date: 6-25 days

The chloride ion-selective electrode (ISE) is widely employed in environmental monitoring, medical diagnostics, and industrial processes where accurate Chloride measurements are essential. It offers advantages such as high sensitivity, rapid response, and ease of use, making it a valuable sensor in various fields for quantifying Chloride levels in diverse sample matrices.

Specification

Model CCHN-PCl-1-01
Electrode Type Single Electrode
Ion Chloride Ion (Cl-)
Standard Solution KCl Solution
Measuring Range 5 x 10-5~10-1mol/L
1.8mg/L~3.55g/L
Ionic Strength Adjuster (Powder) Small Amount of KNO3
High-end Ionic Strength Regulator Ionic Strength Regulator Type Ⅰ
Sensitive Film Material Crystal Film
Shell Material Plexiglass
Working Temperature 5℃~60℃
Interface BNC (Q9)
Dimension φ12*120mm
Recommend Reference Electrode CCHN-CK2SO41


Dimension

Chloride ion selective electrode ISE dimension

Detail

Chloride ion selective electrode ISE detail

Application

Ion selective electrode ISE application

Tips: What are the factors affecting the performance of a chloride ion selective electrode?

The performance of a chloride ion-selective electrode (Cl-ISE) is influenced by several key factors. Firstly, the membrane composition plays a crucial role, affecting the selectivity and sensitivity of the electrode. The type and concentration of ionophores, lipophilic additives, and plasticizers in the membrane impact the electrode's response to chloride ions. Additionally, the quality and thickness of the membrane influence the diffusion kinetics of chloride ions. The reference electrode used, typically a silver/silver chloride electrode, also contributes to performance. External factors such as temperature and pH can impact the electrode's response, necessitating proper calibration and compensation. Maintenance and storage conditions, including proper cleaning procedures, are vital for prolonged electrode functionality. Overall, a comprehensive understanding and control of these factors are essential for optimizing the accuracy and reliability of chloride ion measurements using selective electrodes.