Fixed Sulfur Dioxide (SO2) Gas Detector, 0 to 20/50/100 ppm

Favorable price SO2 sulfur dioxide gas detector with alarm light is a 24h continuously wall mounted type gas detector which can detect SO2 in different kinds of situations. Measuring range 0 to 20/50/100 ppm, powered by 24V DC, with 4-20mA, RS485, relay signal output.
SKU: GD300-SO2
30-day Returns
Free Shipping
Delivery date: 6-25 days

Economical price fixed SO2 sulfur dioxide gas detector uses high quality sensors, and advanced micro-process technology, with data display and high/low alarm, fast response, high precision and good stability. Explosion proof, suitable for different kinds of situations.

Specification

Model GD300-SO2
Detection Principle Electrochemistry
Gas Sulfur Dioxide (SO2)
Range (Optional) 0 to 1ppm, 0 to 5ppm, 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm, 0 to 500ppm, 0 to 1000ppm
Resolution 0.001ppm(0-1/5ppm), 0.01ppm (0-10/20/50ppm), 0.1ppm (0-100ppm), 1ppm (0-500/1000ppm)
Calibration Kit Gas pressure regulator (calibration gas cylinder NOT included)
Accuracy ≤±3% F.S.
Response Time ≤10s
Repeatability ≤±1%
Recovery Time ≤10s
Linearity Error ≤±1%
Zero Shift ≤±1% (F.S./year)
Signal Output (Optional) 4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional).
Alarms Sound, light
Display High light nixie tube display
Installation Wall-mounted, piping type, flow-type (according to the detected environment)
Connection Power connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time 24h
Explosion-proof Grade II 2G Ex ia IIC T4 Ga
Protection Grade IP65
Certification CE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage 12-36V DC
Case Material Die-casting aluminum housing
Operating Temperature -20℃~50℃
Operating Humidity 0~95%RH (non-condensing)
Dimension 206*179*90mm
Weight ≤1.6kg
Power Adapter Input 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional) Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note: To measure confined spaces such as pipelines, please contact us and inform the detailed conditions of use.

Fixed Gas Detector Dimension (Unit: mm)

Fixed gas detector with alarm dimension

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas Type Measure Range Resolution
Ammonia (NH3) 0-50/100/200/500/1000/2000/5000ppm 0.01ppm/0.1ppm/1ppm
Benzene (C6H6) 0-1/10/50/100/200/1000/2000/5000/10000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2) 0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL 0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO) 0-10/20/50/100/500/1000/2000ppm 0.01ppm/0.1ppm/1ppm
Chlorine (Cl2) 0-5/10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2) 0-1/5/10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX) 0-100%LEL 1%LEL
Ethylene (C2H4) 0-10/20/50/100/500/1000/2000ppm 0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O) 0-10/20/50/100/500/1000ppm 0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC) 0-100%LEL 1%LEL
Hydrogen (H2) 0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL 0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL) 0-10/20/50/100/200ppm 0.01ppm/0.1ppm
Hydrogen Cyanide (HCN) 0-10/20/50/100ppm 0.01ppm/0.1ppm
Hydrogen Sulfide (H2S) 0-5/20/50/100/200ppm 0.001ppm/0.01ppm/0.1ppm
Methane (CH4) 0-50/100%VOL, 0-100%LEL 0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO) 0-1/5/10/20/50/100/250/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2) 0-99.99/0-100%VOL 0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2) 0-1/5/10/20/50/100/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX) 0-1/5/10/20/50/100/250/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2) 0-25/30/100%VOL 0.01%VOL/0.1%VOL
Ozone (O3) 0-1/5/10/20/50/100ppm 0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3) 0-10/20/50/100/500/1000/2000/3000ppm 0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2) 0-1/5/10/20/50/100/500/1000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC) 0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm 0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Sulfur Dioxide (SO2) Gas Detector Details

Application

Applications of Portable Multi Gas Detector

Tips: Gas detector troubleshooting

  • The number cannot be displayed correctly
    If the gas detector has been used for a long time, or it has not been calibrated for a long time, there will be a problem of incorrect readings. We all know that the gas detector is mainly detected by the internal sensor. The sensor has a certain life. When used for a certain number of times, the sensitivity of the sensor decreases, which affects the detection result. In addition, if the calibration is not carried out for a long time, the test results will also be affected.
  • The gas detector cannot inhale
    This type of problem mainly occurs on pump-aspirated gas detectors. A small suction pump inside the detector is used to inhale gas for detection. Once the suction pump is damaged or other failures, the gas detector will not be able to inhale. This problem is easy to deal with, and a new suction pump can be replaced.
  • The gas detector fails
    Such faults are prone to occur in special working environments, such as the presence of a lot of dust and oil in the detection environment, which will contaminate the gas detector and lead to failure. In such an environment, the gas detector needs to be cleaned.