Close
Shopping Categories
Search

Handheld Multi-Gas (4-Gas) Detector, CO, H2S, O2, LEL

Handheld multi-gas detector provides 4 gases detection, monitoring CO (0-1000ppm), H2S (0-100ppm), O2 (0-30%VOL), EX (0-100%LEL) with high accurate sensors, and give sound, light and vibration alarms, light weight and mini size, portable and easy to carry, long battery life, reliable quality and low price.
SKU: GD500-4GAS
30-day Returns
Free Shipping
Delivery date: 6-25 days

Handheld multi gas detector can measure 4 gases (CO, H2S, O2, LEL) at the same time with high accuracy and reliability, min size and high protability, and it is widely used in oil, metallurgy, chemical, medical, agriculture, refinery and other industries.

Features

  • Adopt high precison sensors
  • LCD dot matrix display, , support Chinese and English operation, easy to read
  • Gas unit ppm and mg/m3 can be switched quickly
  • One key to check the battery capacity and voltage.
  • One press to restore factory settings.
  • Alarm with ultra-high buzzer sound and light, high and low alarm values are settable
  • Rechargeable lithium polymer battery with high capacity enables long working time
  • With a alligator clip, easy to carry around
  • Rugged and durable housing, comfortable touch
  • Data storage function: Can record 100,000 data, and historical data can be viewed on the device (optional function).

Specification

Model GD500-4GAS
Sampling Method Diffusion
Detection Principle Electrochemistry (CO, H2S, O2), Catalytic Combustion (LEL)
Gas Carbon Monoxide (CO), Hydrogen Sulfide (H2S), Oxygen (O2), Combustible (LEL)
Range CO: 0 to 1000ppm, H2S: 0 to 100ppm, O2: 0 to 30% VOL, EX: 0 to 100% LEL
Resolution CO: 1ppm, H2S: 0.1ppm, O2: 0.1% VOL, EX: 1% LEL
Accuracy ≤±3%F.S.
Display Monochrome dot matrix 128*128 LCD graphic display
Backlight Backlight time is settable; the backlight will be auto-on when alarming.
Data Logging (Optional Function) Storage capacity of over one hundred thousand sets. Interval times ranging from 10~3600 seconds are settable.
Alarms Sound, light and vibration
Operation Language Chinese/English
Gas Unit Gas units ppm and mg/mare switchable
Battery 3.7V rechargeable lithium battery with 2300mAh capacity, operating time is about 10-12h
Charger Travel charger with USB. The typical charge time is 4-6 hours.
Explosion-proof Grade II 2G Ex ia IIC T4 Ga
Certification CE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Case Material ABS+PC
Protection Grade IP65
Operating Temperature -20℃~50℃
Operating Humidity 0~90%RH (non-condensing)
Dimension 131*85*35mm
Weight 240g


Details

Handheld Multi Gas Detector Details

Tips: What does it mean, the gas units PPM, %LEL, %VOL in multi-gas detector's specification?

1. PPM
PPM refers to parts per million, a unit of gas volume concentration.
For solution: it means that there’s 1/1000 ml solute in the 1L aqueous solution, so its concentration is 1ppm.
For gas: it’s one of representation method of pollutant concentration in the ambient atmosphere (air).
2. %LEL
LEL refers to the lower explosive limit. When the combustible gas reaches 100%LEL, it’s easy to explode, and the explosion occurs as soon as contacting an electric spark. Therefore, 0-100%LEL generally refers to the range of combustible gas measurement. For example, hydrogen: 4%VOL=100%LEL, methane: 5%VOL=100%LEL.
3. %VOL
VOL refers to the volume ratio of target gas in per volume. It’s generally used for high concentration. 1%VOL is equal to 10000PPM, and generally it is for oxygen and combustible gases. For example, how much oxygen in a space.