Digital Panel Meter for Displacement Sensor 4 Digit

Single channel digital panel meter cooperate with all kinds of analog output sensor and transmitter, realize measurement, conversion, display, transmitting, record and control, zero clearing at any time.
SKU: CCHN-DPM-DS4D
30-day Returns
Free Shipping
Delivery date: 6-25 days

Intelligent digital panel meter has adjustment and digital filtering function. The digital display controller can be used for various sensors and transmitters, such as temperature sensor, pressure sensor, flow sensor, level sensor, displacement sensor, AC/DC current sensor and transmitter with 4-20mA/0-5V/0-10V analog output, etc.

Specification:

Basics Model CCHN-DPM-DS4D-CH6
PDF Digital panel meter user manual
Dimension (W*H*L) D1: 160*80*125mm horizontal, hole size 152*76mm;
D2: 80*160*125mm vertical, hole size 76*152mm;
D3: 96*96*76mm, hole size 92*92mm;
D4: 96*48*82mm horizontal, hole size 92*45mm;
D5: 48*96*82mm vertical, hole size 92*45mm;
D6: 72*72*75mm, hole size 68*68mm;
D7: 48*48*108mm, hole size 45.5*45.5mm.
Shipping weight 2 kg
Technical parameters Display -1999~9999
Measurement accuracy <0.5%
Measuring speed 10 times/second
Display method 4 digit LED display; 4 digit LED display + setting
Instrument power supply 100-240VAC, 50/60Hz
Universal signal input DC current 4-20mA, 0-20mA, 0-10mA;
DC voltage 0-5V, 1-5V;
RTD sensor: Pt100 (-200~+500℃), Cu100 (-50~+150℃), Cu50 (-50~+150℃), BA1 (-200~+650℃), BA2 (-200~+500℃), G53 (-50~+150℃);
Thermocouple: K type (-100~+1300℃), S type (0~+1700℃), R type (0~+1700℃), B type (500~1800℃), N type (-100~+1300℃), E type (-100~+800℃), J type (-100~+1100℃), T type (-100~+400℃).
*Note: DC voltage 0-10V input need to be customized and can't be a universal signal input.
Alarm AH and AL alarm (2-channel relay output)
Additional power supply (optional) P0: No power supply;
P1: DC 24V±5%, <50mA;
P2: DC 12V±5%, <50mA.
*Note: Additional power supply can provide DC power supply for other devices such as sensors.
Output signal (optional) T0: No output signal;
T1: Current output (4-20mA), (0-10mA), (0-20mA);
T2: Voltage output (0-5V), (1-5V);
T3: Voltage output (0-10V).
*Note: DC voltage 0-10V output need to be customized.

Tips: How to set digital panel meter for displacement sensor?
The parameters of digital panel meter for displacement sensors generally include the upper limit of measured value, the lower limit of the measured value, the upper limit of deviation, the lower limit of deviation, the absolute value of the deviation. For example, the upper (lower) limit of measured value is used to set the maximum (minimum) measuring range of the displacement. It is used to display the displacement value delivered to the DCS control system.