| Model |
CCHNWG8-40S1206 |
CCHNWG8-40S1210 |
CCHNWG8-40S1220 |
| Absolute Maximum Ratings |
| Operating Ambient Temperature |
-40-50℃ |
| Shell Ambient Temperature |
-40-80℃ |
| Storage Temperature |
-55-100℃ |
| Operating Humidity |
5-95% (Non-condensing) |
| Atmospheric Pressure |
62-106Kpa |
| Altitude |
4000m |
| Cooling Way |
Natural Cooling |
| Input Characteristics |
| Input Voltage |
8-40V (Typ. 12/24) |
| Max. Input Voltage |
40V (Continuous) |
45V (Continuous) |
| Undervoltage Shutdown |
7.8-8.2V (Automatic Recovery) |
7.3-8.2V (Automatic Recovery) |
| Undervoltage Recovery |
8.5-8.7V (Automatic Recovery) |
7.6-8.2V (Automatic Recovery) |
| Max. Input Current |
11.3A (Vin=8.1V; Iout =6A) |
18A (Vin=8.1V; Iout =10A) |
33A (Vin=8V; Iout =20A) |
| No Load Current |
47mA (Vin=12V) |
55mA (Vin=12V) |
50mA (Vin=12V) |
| Positive Electrode Cable |
16 AWG (If the wire length is greater than 50cm, it is recommended to use a thicker wire diameter.) |
14 AWG (If the wire length is greater than 50cm, it is recommended to use a thicker wire diameter.) |
12 AWG (If the wire length is greater than 50cm, it is recommended to use a thicker wire diameter.) |
| Negative Electrode Cable |
| Enable Pin Cable |
22 AWG (If the product has this feature) |
N/A |
| Fuse |
30A (Input positive has built-in fuse) |
40A (Input positive has built-in fuse) |
| Output Characteristics |
| Efficiency |
90.8% (Vin=12V; Iout=6A) |
90.8% (Vin=12V; Iout=10A) |
96% (Vin=12V; Iout=20A) |
| Output Voltage |
11.9-12.3V (Vin=12V; Iout=6A) |
11.9-12.3V (Vin=12V; Iout =10A) |
11.8-12.4V (Vin=12V; Iout =20A) |
| Regulator Accuracy |
±1% |
±5% |
| Voltage Regulation |
±3% |
| Load Regulation |
±3% |
| Overvoltage Protection |
N/A |
45.5-47.0V |
| Output Current |
0-6A |
0-10A |
0-20A |
| Overcurrent Protection |
9.7-10.2A (Vin=12V) |
16.3-16.7A (Vin=12V) |
21-24A (Vin=12V) |
| External Capacitance |
0-4000μF |
μF (Don' t Need) |
| Output Ripple and Noise |
130mVp-p (Vin=8-40V; Iout=6A, Oscilloscope Bandwidth: 20 MHz) |
230mVp-p (Vin=8-40V; Iout=10A, Oscilloscope Bandwidth: 20 MHz) |
250mVp-p (Vin=8-40V; Iout=20A, Oscilloscope Bandwidth: 20 MHz) |
| Output Voltage Rise Time |
5.0mS |
4.8mS |
30mS |
| Boot Delay Time |
14mS |
15mS |
35mS |
| Out Voltage Overshoot |
2% (Vin=12V, 50%-75% Load Step) |
| Over Temperature Protection |
N/A |
85℃ (Shell) |
| Short Circuit Protection |
Yes (Long-term (4h) Short Circuit is Not Damaged, Hiccup Mode) |
| Positive Electrode Cable |
16 AWG (If the wire length is greater than 50cm, it is recommended to use a thicker wire diameter.) |
14 AWG (If the wire length is greater than 50cm, it is recommended to use a thicker wire diameter.) |
| Negative Electrode Cable |
| Safety and EMC Features |
| Anti-electric Strength |
| Input to Output |
N/A |
| Input to Shell |
≥500V (Leakage Current ≤ 3.5mA, 1min, No Breakdown, No Arcing) |
| Output to Shell |
| Insulation Resistance |
| Input to Output |
≥50MΩ (Test Voltage =500V) |
| Input to Shell |
| Output to Shell |
| Other Characteristics |
| Weight |
About 290g |
| Package |
White Box |
| MTBF |
≥200000H |
| Switching Frequency |
80±10kHz |
150±10kHz |